PICATINNY ARSENAL
Rockaway Township, New Jersey
In August 2014, we were awarded a 50-year contract to own, operate, renew and replace the potable water, service water, and wastewater systems serving Picatinny Arsenal in Rockaway Township, New Jersey.
The systems serve over 1,000 buildings on 6500 acres. The potable water utility system at Picatinny Arsenal was initially constructed in the 1920s and includes four wells, 11 pumping stations, nine tanks, and about 40 miles of potable water distribution pipe. The service water systems for industrial processes include six tanks, seven pump stations, a 2.0 million gallons per day (MGD) water treatment plant (WTP) and approximately 30 miles of service water distribution mains.
The wastewater collection system consists of 19 sewage lift stations, over 400 manholes, and approximately 27 miles of pipe/force mains that transport wastewater off post to the Rockaway Valley Regional Sewage Authority.
VENDOR INFORMATION AND FORMS
STANDARD SPECIFICATIONS
Division 1 - General Requirements
Division 3 - Concrete
- 03 30 00 - Cast-In-Place Concrete
- 03 48 10 - Precast Concrete Manholes
- 03 48 20 - Valve Boxes and Meter Vaults
- 03 90 00 - Manhole Rehabilitation
Division 5 - Metals
Division 9 - Finishes
Division 22 - Plumbing
- 22 11 16.11 - Water Tap and Service Installation
- 22 11 16.13 - Cross Connection Control
- 22 13 19.23 - Grease Traps
- 22 13 20 - Oil/Water Separator
Division 25 - Integrated Automation
Division 26 - Electrical
- 26 00 10 - General Electrical Requirements
- 26 00 20 - Electrical Materials and Methods
- 26 29 33 - Variable Frequency Drives
- 26 32 13.13 - Emergency Generator
- 26 36 23 - Automatic Transfer Switch
Division 31 - Earthwork
- 31 11 00 - Clearing and Grubbing
- 31 23 23 - Utility Backfill Materials
- 31 23 33 - Excavation Backfill and Compaction for Utilities
- 31 50 00 - Casing Installation
Division 32 - Exterior Improvements
- 32 01 00 - Pavement Repair and Restoration
- 32 13 13 - Concrete Curb, Drives and Sidewalks
- 32 92 00 - Turf and Grasses
Division 33 - Utilities
- 33 01 10.13 - Pressure and Leakage Tests
- 33 01 10.15 - Disinfecting Pipeline
- 33 01 30.13 - Acceptance Testing for Sanitary Sewers
- 33 01 30.51 - Pumping and Bypassing
- 33 05 23.13 - Horizontal Directional Drilling
- 33 05 27 - Tracer Wire
- 33 05 29.11 - Stream Crossing
- 33 05 29.13 - Bridge Crossing
- 33 11 00 - Piping and Accessories - General Provisions
- 33 11 00.11 - Polyvinyl Chloride (PVC) Pipe
- 33 11 00.13 - High Density Polyethylene (HDPE) Pipe
- 33 11 00.15 - Ductile Iron Pipe and Fittings
- 33 11 00.17 - Polyethylene Wrap
- 33 11 00.19 - Abandonment of Water Mains
- 33 11 00.21 - Cured-In-Place Pipe
- 33 12 16.11 - Gate Valves
- 33 12 16.13 - Butterfly Valves
- 33 12 16.15 - Pressure Reducing Valves
- 33 12 16.17 - Tapping Sleeves and Valves
- 33 12 16.19 - Air Release Valves
- 33 12 19 - Fire Hydrants
- 33 12 33 - Water Meters
- 33 16 13 - Ground Storage Tanks
- 33 16 13.11 - Water Storage Tank Disinfection
- 33 16 13.12 - Water Storage Tank Removal
- 33 21 00 - Drinking Water Well Requirements
- 33 31 00.11 - Gravity Sanitary Sewers
- 33 31 00.13 - Abandonment of Sewer Mains
- 33 31 00.15 - Sanitary Sewer Laterals
- 33 32 16 - Packaged Sanitary Lift Stations
- 33 32 16.15 - Medium Sized Lift Stations
- 33 32 17 - Grinder Lift Stations
- 33 34 00 - Sanitary Sewer Force Mains
STANDARD DETAILS
General
- MSG-ST-01 - General Water and Sewer Construction Notes (1 of 2)
- MSG-ST-01A - General Water and Sewer Construction Notes (2 of 2)
- MSG-ST-02 - Trench Restoration
- MSG-ST-03 - Jack and Bore Detail
- MGS-ST-04 - Electrical Safety
- MSG-ST-05 - Required Separation between Water Mains and Sanitary Sewers
- MSG-ST-06 - Chain-Link Fence
- MSG-ST-07 - Concrete Encasement Detail
Wastewater
- MSG-WW-01 - Standard Small Lift Station Detail
- MSG-WW-02 - Standard Small Lift Station Electrical Plan
- MSG-WW-03 - Pump Station Details
- MSG-WW-04 - Emergency Pump Connection Detail
- MSG-WW-05 - Standard Medium Lift Station Typical Layout Detail
- MSG-WW-06 - (RESERVED)
- MSG-WW-07 - Clean Out Detail
- MSG-WW-08 - (RESERVED)
- MSG-WW-09 - Standard Precast Manhole Detail
- MSG-WW-10 - Typical Outside Drop Connection Detail
- MSG-WW-11 - Doghouse Manhole Detail
- MSG-WW-12 - Connection to Existing Manhole Detail
- MSG-WW-13 - Manhole Steps Detail
- MSG-WW-14 - Manhole Frame and Cover Detail
- MSG-WW-15 - Manhole Vent
- MSG-WW-16 - Sanitary Sewer Lateral Detail
- MSG-WW-17 ( RESERVED)
- MSG-WW-18 - Force Main Discharge Manhole
- MSG-WW-19 - Force Main Cleanout
- MSG-WW-19A - Force Main Dual Cleanout Detail
- MSG-WW-20 - Sewage Air Release Valve
- MSG-WW-21 - Grease Trap
Water
- MSG-W-01 - Water Service Installation for 2" Meters
- MSG-W-01A - Water Service Installation for Smaller than 2" Meters
- MSG-W-02 - Shallow Bury Air Release Valve Assembly Detail
- MSG-W-03 - Gate Valve Box Pad Detail
- MSG-W-04 - Concrete Valve Box Pad Detail
- MSG-W-05 - Tracer Wire for Non-Conductive Pipe Detail
- MSG-W-06 - Tapping Sleeve and Valve Detail
- MSG-W-07 - Fire Hydrant Detail
- MSG-W-08 - Thrust Block Details
- MSG-W-09 - 3" and Larger Meter Vault Detail
- MSG-W-10 - Fire Hydrant Construction Meter Detail
- MSG-W-11 -Yard Hydrant
- MSG-W-12 - (RESERVED)
- MSG-W-13 - Cutting-In Sleeve and Valve Installation Detail
- MSG-W-14 - Concrete Blocking Pad Detail
- MSG-W-15 - Blow-off Assembly Detail
- MSG-W-16 - Automatic Flushing Assembly Detail
- MSG-W-17 - 3/4"-2" DC Backflow Preventer - Exterior
- MSG-W-18 - > 2" DC Backflow Preventer - Exterior
- MSG-W-19 - 3/4" - 2" DC Backflow Preventer - Interior
- MSG-W-20 - > 2" DC Backflow Preventer - Interior
- MSG-W-21 - 3/4"-2" RPZ Backflow Preventer - Exterior
- MSG-W-22 -> 2" RPZ Backflow Preventer - Exterior
- MSG-W-23 - 3/4" - 2" RPZ Backflow Preventer - Interior
- MSG-W-24 - > 2" RPZ Backflow Preventer - Interior
- MSG-W-25A-HDPE Connection Restraints
- MSG-W-25B-HDPE Connection Restraints
- MSG-W-29- Above Ground Sampling Station
DESIGN GUIDE
Military Services Group Design Guide (Jan 2023)
STANDARD SPECIFICATIONS AND DETAILS REVISIONS LOG
ADDITIONAL DOCUMENTS
NEW JERSEY LEAD SERVICE LINE REQUIREMENTS
Click here to view the Picatinny Lead Service Line Inventory
At American Water, providing safe, reliable water service is our top priority. In July 2021, the state of New Jersey enacted legislation for all water providers to share with customers the material of the utility-owned service lines leading to their properties and the material of the customer-owned service lines leading to their properties, if known. It also requires utility companies to replace utility-owned and customer-owned lead service lines within the next ten years.
Please note if your service lines contain lead, it does not mean you cannot use water as you normally do. Your water continues to meet water quality standards. The company regularly tests for lead in drinking water and our water meets state and federal water quality regulations, including those set for lead. For added protection and to comply with the new legislation, we will be removing lead and lead/galvanized piping from service lines over time.
Picatinny Arsenal’s water system is in full compliance of the Lead and Copper Rule. For additional information on Lead Service Line Requirements, please visit the New Jersey Department of Environmental Protection.
To contact Picatinny Arsenal administrator or Project Manager, please email Picatinny.Arsenal@amwater.com or contact 862-397-5990.